MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 4/29/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Car top light shall work. 8/25/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 8/25/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x Emergency stop switch shall be inoperable on Phase 2 fire service. 3/31/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light shall work. 8/25/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Shorten the hoist ropes. 8/25/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates The fire service phase one key switch bezel shall be legible.
MO Minimum : Elevators (F) - Electrical Switches (F)1 x The in car stop key switch shall be rendered inoperative once the car is in motion while returning to the egress floor in phase one fire service. 9/6/2023
MO Minimum : Elevators (F) - Electrical Switches (F)8 x The upper pit switch is seized in the run position and shall be repaired or replaced. 9/6/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x This elevator is out of service. needs new ropes. 3/29/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Two-way communications device is not functioning and needs repair.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site.