Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test counterweight buffer at rated speed. Re-inspection required 10/19/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test car buffer, rated load & speed. Re-inspection required 10/19/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test car safeties, rated load & speed. Re-inspection required 10/19/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test machine brake with 125% rated load. Re-inspection required 10/19/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate Replace illegible capacity plate in car
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate Need to replace illegible capacity plate in car
MO Minimum : Elevators (I) - Pits (I)1 Clean pit
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Suspension ropes are below minimum diameter and are rouged, replace suspension ropes. Re-inspection required 10/19/2022
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Suspension means, diameter loss due to rouging exceeds proposed criteria. Needs replacement within 90 days. 11/22/2019
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 x Counterweight runby is under minimum distance of 6". Hoist ropes need to be shortened. Re-inspection required 9/30/2024
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 x Hoist ropes need to be shortened. Runby is below minimum of 6". Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2 Replacement of Suspension Means (Re-Inspection) x Suspension ropes are below minimum diameter and are rouged, need to be replaced. Re-inspection required 9/30/2024