MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean pit
|
|
A17.1-2016 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
2.4.2
|
x
|
|
Counterweight runby is under minimum distance of 6". Hoist ropes need to be shortened. Re-inspection required
|
9/30/2024
|
A17.1-2016 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
2.4.2
|
x
|
|
Hoist ropes need to be shortened. Runby is below minimum of 6". Re-inspection required
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)9 Capacity Plate
|
|
|
Need to replace illegible capacity plate in car
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)9 Capacity Plate
|
|
|
Replace illegible capacity plate in car
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Suspension means, diameter loss due to rouging exceeds proposed criteria. Needs replacement within 90 days.
|
11/22/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.2 Replacement of Suspension Means (Re-Inspection)
|
x
|
|
Suspension ropes are below minimum diameter and are rouged, need to be replaced. Re-inspection required
|
9/30/2024
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Suspension ropes are below minimum diameter and are rouged, replace suspension ropes. Re-inspection required
|
10/19/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test car buffer, rated load & speed. Re-inspection required
|
10/19/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test car safeties, rated load & speed. Re-inspection required
|
10/19/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test counterweight buffer at rated speed. Re-inspection required
|
10/19/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test machine brake with 125% rated load. Re-inspection required
|
10/19/2022
|