Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Demarcation lights top and bottom are out. Recommend truss and pit clean down. 8/31/2022
conversion conversion n/a No No Demarcation lights top and bottom are out. Recommend truss and pit clean down. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Need to replace broken step demarcation strip. Re-inspection required
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Replace left handrail. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Right handrail is cracked. Replace handrail 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Left handrail has cracks, needs to be replaced 12/1/2024
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(K) No No Replace left handrail. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(H) No No All demarcation lights shall work. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(E) No No Bad comb impact switch. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(E) Yes No Replace broken comb plate at top landing. Re-inspection required 11/7/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(D) No No Repair bad step chains. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(D) No No Broken weld on step track. 8/31/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) No Yes Failed brake test. Red tagged out of service until repaired and reinspected. 8/28/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test is incomplete, need to perform test to check tripping pressure of upper and lower comb plate impact devices & perform step indexing test. Re-inspection required