Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 7.10 - Operating and safety devices (NR 8.6.10.5) No No Stop switch cover shall have audible alarm. 9/24/2025
A17.1-1996 : Escalators 7.3 - Handrails 802.2 No No Replace left handrail. 9/24/2025
A17.1-1996 : Escalators 7.15 - Balustrades 802.3 No No Refasten upper deck guard on right hand side. 9/24/2025
A17.1-1996 : Escalators 7.15 - Balustrades 802.3 No No Upper deck guard on right hand side needs to be refastened. 9/24/2025
A17.1-1996 : Escalators 7.3 - Handrails 802.4 No Yes Right handrail needs to be replaced due to major cracks causing pinching hazard. Red tagged escalator. 3/25/2021
A17.1-1996 : Escalators 7.5 - Lighting 806.2 No No Repair upper demarcation lighting. 7/2/2019
conversion conversion conversion - reinspect Yes No Handrail on right side (looking up) has a break - test incomplete need to perform step indexing 4/16/2018