Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Car lighting illuminates insufficiently. 1/5/2021
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 Cylinder drain line needs to drain into pit container of no more than a 5 gallon container 1/5/2021
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation Test and log firefighter operation monthly
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 Post In Case of Fire signage next to hall button fixture at each landing
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Current state operating certificate not displayed in machine room
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 210.4 Car lighting disconnect is not lockable in the open position
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed
A17.1-2016 : Elevators 2.4 - Machine space 8.6.4.8 Machine Room and Machinery Space x FIRE RATE TOP OF MACHINE ROON 8/15/2024
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 3.27.3 Device Actuation at Recall Level x x BUILDING NEEDS TO ADD ANOTHER FIRE SERVICE RELAY TO SEPERATE THE DETECTORS IN THE MACHINE ROOM FROM THE TOP OF THE HOISTWAY 8/15/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x emergency phone does not operate 7/29/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not provide two way conversation. Phone dials out but there is no answer. 7/17/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light does not illuminate 7/13/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not operate 7/13/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not operate 12/18/2020