MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Light bulbs in car are not protected. Replace missing ceiling panels or install plastic tubes and end caps on bulbs.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Fire extinguisher in machine room is expired, have serviced or replaced
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone in car does not work. Re-inspection required
|
1/25/2024
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
The following tests need to be pperformed to complete inspection: full load, full speed safeties test, full load, full speed car buffer test, 125% lower and hold brake test, 125% unintended movement (emergency brake) test, no load, full speed counterweight buffer test, fireman's emergency service. Re-inspection required
|
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
1001.2(b)(15)
|
x
|
x
|
Emergency brake failed to hold car when actuated without main brake applied. Repair brake and perform uncontrolled motion test.
|
10/28/2019
|
A17.1-1996 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
1001.2(e)(2)
|
x
|
|
Perform counterweight buffer test.
|
11/12/2019
|