Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone in car does not work. Re-inspection required 1/25/2024
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 202 x Traveling sheave on counterweight has unusual wear pattern in rope grooves, repair or replace sheave. Re-inspection required 10/6/2023
A17.1-1996 : Elevators 3.25 - Car, overhead, and deflector sheaves 208 x Traveling sheave on car top has unusual wear pattern in rope grooves, repair or replace sheave. Re-inspection required 10/6/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The testing has not been completed on the elevator at this time. The fireman’s service, back-up emergency systems, door pressure, safeties set, and seismic device before the inspection is completed. 10/27/2022
A17.1-1996 : Elevators 3.25 - Car, overhead, and deflector sheaves 208 x The car traveling sheave has unusual wear in an outside groove. This is questioning the integrity of the sheave as the thickness of the sheave is not equal in the other grooves. The sheave shall be repaired or replaced and integrity of the sheave examined for any abnormalities. 10/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Need to replace missing fire service Phase 2 instructions sign in car