Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The following tests must be performed to complete Cat 5 inspection: full load, full speed safeties, full load, full speed car buffer test, fireman's service testing. Re-inspection required
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone in car does not work. Re-inspection required 1/25/2024
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 202 x Traveling sheave on counterweight has unusual wear pattern in rope grooves, repair or replace sheave. Re-inspection required 10/6/2023
A17.1-1996 : Elevators 3.25 - Car, overhead, and deflector sheaves 208 x Traveling sheave on car top has unusual wear pattern in rope grooves, repair or replace grooves. Re-inspection required 10/6/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Need to replace missing fire service Phase 2 instructions sign in car 12/4/2024
A17.1-2016 : Elevators 2.17 - Drive machine brake 8.6.4.20.4 x x Drive machine brake failed 125% testing. Red-tagged and removed from service until repairs can be made. Re-inspection required