Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Elevator car top shall remain clean to prevent any hazards
MO Minimum : Elevators (I) - Pits (I)1 Elevator pit shall be clean of all debris
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Elevator pit light shall work with a minimum of 5 foot candles.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up to date operating certificate is required in the machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lighting shall work. No less than 10 foot candles at floor level.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A code compliant MCP and all the on-site documentation required shall be provided in the machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)8 Missing junction box covers on fire service wiring.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Basement hall button plate needs to be mounted securely.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates "In case of fire" pictograph is missing at call stations.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Basement Braille tag is missing.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Re-install the cover on the open air vent by the elevator equipment.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone shall work. 12/20/2024
MO Minimum : Elevators (H) - Machine Rooms (H)8 x Lockable disconnect required. Circuit breaker shall be lockable. 12/20/2024
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 8.6.4.20.2 x x The maximum tripping speed for the governor is 452 fpm. It is not tripping until 500 fpm. Elevator Red Tagged. 12/20/2024
MO Minimum : Elevators (H) - Machine Rooms (H)8 x Lockable disconnect required. Circuit breaker shall be lockable. (Not corrected as of 12/20/24 re-inspection)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone shall work. (Not corrected as of 12/20/24 re-inspection)
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Repair inoperable emergency phone. 4/17/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Replace earthquake halo on counterweight frame. 4/15/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone not working. 4/15/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work on 110v emergency power or normal power. Repair or replace 11/27/2023