Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4 Instructions for Locating Maintenance Records incomplete mcp on site
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) crosshead data tag shows 13 mm hoist ropes are to be used elev. has 1/2 '' ropes on rope data tag when using go no go gage 1/2 " rope pass 12/15/2022
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) hoistropes rouged an undersized 12/15/2022
A17.1-1996 : Elevators 2.19 - Gears, bearings, and flexible couplings 1001.2(b)(17) x Excessive rouge on drive machine. 12/10/2019