A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency light battery is dead and needs to be replaced
|
7/27/2022
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
emergency phone line is dead, provide a working phone line to the elevator controller
|
7/27/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
inspection tag on the fire extinguisher in the machine room is from 2019, have the fire extinguisher inspected and tagged annually
|
6/14/2024
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.11.3.1.2(j)
|
|
|
Machine room fire extinguisher last checked in 2019
|
6/14/2024
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.4.1(c)(2)
|
|
|
monthly fire service test log is to be kept in the machine room
|
6/14/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.11.1 Firefighters' Emergency Operation & Documentation
|
|
|
perform a monthly fire service test and fill out the log in the machine room
|
6/14/2024
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2 On-Site Documentation
|
|
|
provide maintenance control program on site documents
|
6/14/2024
|
A17.1-2016 : Elevators
|
1.4 - Sills and car floor
|
8.11.3.1.1(d)
|
|
|
repair the grout in the bottom landing sill, it is crumbling and a trip hazard
|
6/14/2024
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1(a)(3) Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
the backup battery for the emergency phone is not working, phone will not call out when the 110 volt power is off
|
10/16/2023
|
A17.1-1996 : Elevators
|
1.4 - Sills and car floor
|
110.11a
|
|
|
the bottom landing hoistway door sill has not been grouted, there is a gap between the concrete floor and the hoistway door sill
|
6/14/2024
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the copy of the state operating certificate in the machine room is from 2017, post a new copy of the state certificeate in the machine room annually when received from the state
|
6/14/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
the phone line for the emergency phone did not work, provide a working phone line
|
7/26/2023
|
A17.1-1996 : Elevators
|
3.3 - Top-of-car operating device
|
210.1d
|
|
|
the top of car operating device, would not run in the down direction on car top inspection
|
7/26/2023
|