Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems -Vertically Closing hoistway doors do not meet requirements to have automatically closing hoistway doors. A warning bell is required to sound at least 5 seconds before the door starts to close, and a stop switch at landing to stop and reopen the doors. A17.1 1981 Rule 112.3d
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)5 Bulbs and tubes in elevator and machine room shall be guarded to prevent breakage
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)5 Install guard on elevator cab lighting. 9/17/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing car light guard.