Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Phone Failed 8/3/2020
A17.1-2016 : Elevators 2.2 - Headroom 8.11.3.1.2(c) Must Maintain 84" clear head height in Mach Room. (Recently add conduits at 5'-10"must be removed from the Machine room.) 6/27/2023
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.11.3.1.2(j) Must Provide current Test tag on Mach room Fire Extinguisher. 6/27/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.2 Headroom 8.11.2.1.2(b) Must remove or relocate 2-3" conduits above/ Infront of Controller to maintain 7'clear headed height. 6/27/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current State operating Cert. in Mach. room 6/27/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.2 Headroom 2.7.4 Must remove 3" conduit in machine room at 5'-11" height must maintain clear 7" head height in Machine room. 2.7.4 6/21/2023
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post Current State operating Cert. in Machine room. 5.100(2) 6/27/2023
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Must provide current Annual test tag on Machine room Fire Extinguisher. ( currently tagged 5/21) 6/27/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make emergency phone operable. 8.6.4.15 11/22/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make emegency phone operable. 8.6.4.15 6/6/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make Emergency Phone operable. 8.6.4.15 6/12/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make emergency phone operable. 5/26/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone failed 8/16/2019