Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.17 - Standby power operation 8.10.2.3.2(l) x 2.27.2.4.5 After all cars have been recalled on emergency power, If no elevator(s) has been manually selected [switch(es) in “AUTO” position], preference shall be given to cars in Firefighters’ Phase II Emergency In-Car Operation. 1/20/2025
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.1.6(h) Audible/Visual Signal (Re-Inspection) x The fire hat joules in the car shall illuminate intermittently when a Fire Alarm initiating device located in the machine room, control room, and hoistway is activated. 1/20/2025