Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(B) No No The procedure specified by 8.6.11.6.2 shall be utilized when starting an escalator. 7/6/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No A record of authorized personnel trained as specified in 8.6.11.6.2 shall be kept on the premises where the escalator(s) or moving walk(s) or both is located and shall be available to the authority having jurisdiction. Provide list of trained and authorized personnel to inspection company. 7/6/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No The demarcation lights shall be illuminated when running in automatic operation. 6/1/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index Yes No The step/skirt performance index testing required by 8.6.8.15.19 must be performed and witnessed. 6/1/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.4 Escalator Combplates Yes No Comb-step impact devices shall be tested to verify the requirements of 6.1.6.3.13. 6/1/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Testing incomplete. Need to perform step indexing & comb impact devices on upper landing. Re-inspection required 5/11/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Missing step switch at top landing is not working. Repair missing step switch. Red tagged. 8/12/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes Yes Missing step switch at top landing is not working. Repair missing step switch. Red tagged. 8/4/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(G) No No Bottom left skirt deflector needs repair. 6/4/2019
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2 No No Replace broken step treads (7.9) and replace broken comb plate on bottom landing (7.7) 10/3/2018