Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) The fire extinguisher the machine room is expired and shall be replaced by a current testing fire extinguisher.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x Make the door restrictor operational. 5/14/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x In cab emergency telephone shall work. 5/14/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x In car emergency telephone shall work. 10/25/2019
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) The fire extinguisher in the machine room is expired. A current tested ABC type fire extinguisher shall be kept in the machine room.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x The door restrictor shall be operational. 2/23/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 2/23/2021
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The elevator machine room door shall be self-locking and self-closing and shall only be accessible to authorized personnel.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit shall be kept clean. Clean the pit.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit lighting shall be operational.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide a code compliant MCP including onsite documents.
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. Note: The test tag is expired.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x The means to restrict opening of the car door shall be operational. 4/14/2022
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) The car identification number shall be painted on, engraved, or securely attached to the car operating panel and shall be a minimum of 1/2" in height.
A17.1-1996 : Elevators 1.3 - Operating control devices 1001.2(a)(3) The car operating panel car call indicator lights shall all be functional.
A17.1-1996 : Elevators 1.12 - Car enclosure 1001.2(a)(12) The exposed wiring inside the fixture on the back wall of the elevator cab interior shall be enclosed.
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x The in car emergency lighting shall be operational. 4/14/2022
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
A17.1-1996 : Elevators 1.12 - Car enclosure 1001.2(a)(12) Replace the missing handrails in the elevator.
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room.
A17.1-1996 : Elevators 2.6 - Ventilation 1001.2(b)(6) The machine room ventilation shall be operational.
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room.
A17.1-1996 : Elevators 1.3 - Operating control devices 1001.2(a)(3) All lights on the car operating panel shall be operational.
A17.1-1996 : Elevators 1.12 - Car enclosure 1001.2(a)(12) Electrical devices in the car enclosure shall have covers installed.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x The means to restrict opening of the car door shall be operational. 9/14/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x The in car emergency lighting shall be operational. 9/14/2023
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Elevators that are equipped to operate on emergency power shall be tested with no load in the car, operating on emergency power. All cars to be tested. 11/26/2024
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Emergency power testing could not be completed due to failure of auxiliary generator to operate. Take corrective action and re-test.
A17.1-2016 : Elevators 4.1 - Car platform guard 2.15.9 x Platform guard shall not be less than 48". Pit depth results in need of a retractable guard or variance approved by State board. If variance is not approved at next board meeting, unit shall be removed from service until proper guard is installed. 10/25/2023
conversion conversion conversion - reinspect x Car door restrictor shall work. 10/19/2018
conversion conversion conversion - reinspect x In cab emergency telephone shall work. 10/19/2018
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. 4/14/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The safeties shall be tested as required by A17.2, item 2.29. Note: Winding drum safety access is presently covered by glued on flooring. 4/14/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. 9/14/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars The car top shall be cleaned.