Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.11.4.1(e) Lighting (demarcation and step lighting) Repair skirt lights at entrances
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.6.2(i) Step Demarcation Repair skirt lights at upper and lower entrances
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records Provide a complete maintenance control program to include prints
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Post current state certificate in machine room
Missouri Minimum : Escalators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Make repairs to escalator and reschdule to complete overdue inspections with step indexing
conversion conversion n/a Repair skirt lighting 10/19/2018
conversion conversion n/a Post current State certificate in machine room 10/19/2018
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2 Several steps haved shaved off treads, making them like knife blades steps need to be replaced 11/26/2019
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) Need code compliant caution signage and egress of unit 11/26/2019
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Post current State certificate in machine room 12/1/2020
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(H) Repair deck entrance lights 12/1/2020
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x Repair skirt lights at entrance 4/12/2022