Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No 8.11.3.1.1(f) emergency light needs battery 2/21/2020
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Must make Emergency Phone Operable. 8.6.4.15 9/18/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Must make emergency phone operable. 8.6.4.15
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Yes No Must perform Cat. 5 Full load test/insp. for Overspeed Valve within next 90 days. 8.6.5.16.5 9/18/2025
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 No No Must perform Category 5 test on overspeed valve on or before next annual insp. 8.6.5.16.5 1/23/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Must post current operating Cert. in Mach Room 5.100(2) 1/23/2024
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5 Gland Packing and Seals Yes No Must repace jack packing gland to limit oil loss. 8.6.5.5
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5 Gland Packing and Seals Yes No Must repair/replace Jack Packing Gland to limit oil loss. (5 gal pit bucket was full, noted it had been emptied in the last 45 days). 8.6.5.5 5/29/2026
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No needs current certificarte posted 2/21/2020
conversion conversion n/a No No needs maintance record on site 2/21/2020
conversion conversion n/a No No needs record of oil usage 2/21/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4 Instructions for Locating Maintenance Records No No No Records 1/11/2024
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Pit must be kept free of oil. 5.1
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Pit must be kept free of Oil. 8.6.4.7 5/29/2026
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation No No Post monthly fire service log in machine room 1/23/2024
conversion conversion n/a No No rear restrictor needs adjusted or repairerd 2/21/2020
A17.1-1996 : Elevators 2.35 - Supply Line and Shutoff Valve 303 No No Shutoff valve in machine room will not close--needs replaced 3/23/2020