Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Repair pit light 6/15/2020
conversion conversion n/a Install inspection port on pump valve 6/15/2020
conversion conversion n/a Replace leaking jack packing 6/15/2020
conversion conversion n/a Clean pit & remove oil from pit floor 6/15/2020
conversion conversion n/a Install year test tag on governor 6/15/2020
conversion conversion n/a Clean car top--oil 6/15/2020
conversion conversion n/a Rep[air emergency light in car 6/15/2020
MO Minimum : Elevators (I) - Pits (I)1 Clean pit. Remove oil from pit floor. repair pit light, clean oil off car top this is a reinspection item within 30 days max
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service and document on log in machine room
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Replace control valve discharge hose
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service test and document on the log in the machine room. Remove gage and supply valve install test port
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) Provide test procedures in the maintenance control procedures
MO Minimum : Elevators (I) - Pits (I)1 Clean pit
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in the machine room
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service testing and document on log in machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) provide testing procedures in the Maintenance control program
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Repair phone in car 10/16/2023
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing x OSV needs to be tested, tagged & sealed. 8/1/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair emergency light in car 11/19/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 102 x Clean pit remove oil rom floor, repair pit liht 11/19/2020