Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Red Tag) x telephone does not work 5/3/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 1.5 telephone will not call out but alarm still works 4/9/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate needs current certificate posted in machine room 4/9/2020
MO Minimum : Elevators (H) - Machine Rooms (H)4 H(4)/2.5/8.11.2.1.2(e). Non-elevator related items shall not be stored in Machine Room. 5/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 2021&2022 Violation: H(4)/2.5/8.11.2.1.2(e). Non-elevator related items shall not be stored in Machine Room. (Pictures, ) 5/1/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elev Co.) 5/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 H(2) / 101.3d(1)(b) Machine room door shall be self-closing and self-locking ( Door sticks and won't self-close fully) 5/1/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate in machine room 5/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator items from machine room 5/1/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP in machine room 5/1/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Provide current state operating certificate 5/1/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP in machine room 5/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator equipment from machine room 5/1/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate 2021&2022 Violation: 11 CSR 40-5.100(2) : Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. Wrong unit on display (inactive dumbwaiter 2018) 5/2/2024