Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 11/7/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 A record of findings for firefighters' service operation, tested monthly as required by 8.6.11.1 with identification of the person(s) that performed the operation, and the date shall be available on-site. 11/7/2025
A17.1-1996 : Elevators 3.23 - Suspension rope 1202.14 x Counterweight Runby is 1". Shorten suspension ropes. 12/18/2018
MO Minimum : Elevators (E) - Machines (E)4 Hoist rope tail retaining clips shall be properly spaced.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Pit shall be kept clean. Remove rust from all pit equipment, repair/replace as needed. Apply rust prevention treatment to all pit steel, and investigate/repair water leak.
A17.1-1996 : Elevators 3.9 - Floor and emergency identification numbering 100.7 The car identifcation number shall be on the corsshead, at least 2" in height, and visible from the landing.
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x The emergency/standby power shall be tested. 11/7/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.3a(8) Visual and audible signal x The firefighters service visual indicator (fire hat) in the car must illuminate when on firefighters service phase one return. 1/25/2024