Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (E) - Machines (E)4 Hoist rope tail retaining clips shall be properly spaced.
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 The car lighting shall be externally guarded or coated to contain broken glass in case the bulb or tube accidentally breaks.
A17.1-1996 : Elevators 4.2 - Hoistway doors 110 Adjust uptrust roller bearings for proper clerance to door hanger track (10th floor, lower gap >0.75")
A17.1-1996 : Elevators 3.9 - Floor and emergency identification numbering 100.7 Car identification number shall be on the corsshead, at least 2" in height, and visible from the landing.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x The car door shall be restricted from opening when in the closed position anywhere outside the unlocking zone. The car door restrictor is not currently working. 1/25/2024
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 11/7/2025
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x The emergency/standby power shall be tested. 11/7/2025
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 The car lighting shall be externally guarded or coated to contain broken glass in case the bulb or tube accidentally breaks. 11/7/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 A record of findings for firefighters' service operation, tested monthly as required by 8.6.11.1 with identification of the person(s) that performed the operation, and the date shall be available on-site. 11/7/2025