Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Elevator cab phone does not work. Re-inspection required 2/17/2025
MO Minimum : Elevators (I) - Pits (I)2 x All buffer stands & buffer springs in elevator pit are rusted, need to replace all buffer stands & buffer springs in elevator pit. Re-inspection required 2/17/2025
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be clean & dry, pit has 10" of water in it
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light is not working, needs repair
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Elevator cab phone does not work, possible phone line issue, needs repaired. Re-inspection required 4/10/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Elevator phone does not work, possible phone line problem, needs repaired. Re-inspection required 2/17/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to test car safeties with rated load at rated speed. Re-inspection required 2/17/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform 125% of rated load brake test. Re-inspection required 2/17/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to test car safeties with rated load at rated speed. Re-inspection required 2/17/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform 125% of rated brake test. Re-inspection required 2/17/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room