Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) x Repair and install main drive motor fan impeller. 8.6.1.6.1 Unit red tagged until repaired. 5/3/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps x Multiple step tread cleats are damaged, forming a "sharp knife edge". Damaged step treads shall be replaced to conform to code.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x All demarcation lighting shall work.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning Escalator machine space shall be kept clean and free from excessive debris (dust, dirt, oil, etc.). Clean lower pit.
conversion conversion conversion - reinspect x Demarcation lights inoperative 6/19/2018
conversion conversion n/a Demarcation lights inoperative, repair 2/19/2020
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Current state operating permit shall be displayed.