Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
The step index was exceeding the .4 maximum. The index was over .900 on the up unit
|
12/1/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.6 Steps
|
x
|
|
Multiple step tread cleats are damaged, forming a "sharp knife edge". Damaged step treads shall be replaced to conform to code.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
All demarcation lighting shall work.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Escalator machine space shall be kept clean and free from excessive debris (dust, dirt, oil, etc.). Clean lower pit.
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Repair lift skirt seam approximately 6 steps below top landing and re-test step indexing
|
6/19/2018
|
conversion
|
conversion
|
n/a
|
|
|
Upper demarcation lights inoperative
|
1/21/2020
|
conversion
|
conversion
|
n/a
|
|
|
Upper demarcation lights inoperative repair
|
1/21/2020
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Repair left skirt seam 6 steps below top landing and re-test step indexing
|
5/21/2019
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Current state operating permit shall be displayed.
|
|