Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index x The step index was exceeding the .4 maximum. The index was over .900 on the up unit 12/1/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps x Multiple step tread cleats are damaged, forming a "sharp knife edge". Damaged step treads shall be replaced to conform to code.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x All demarcation lighting shall work.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning Escalator machine space shall be kept clean and free from excessive debris (dust, dirt, oil, etc.). Clean lower pit.
conversion conversion conversion - reinspect x Repair lift skirt seam approximately 6 steps below top landing and re-test step indexing 6/19/2018
conversion conversion n/a Upper demarcation lights inoperative 1/21/2020
conversion conversion n/a Upper demarcation lights inoperative repair 1/21/2020
conversion conversion conversion - reinspect x Repair left skirt seam 6 steps below top landing and re-test step indexing 5/21/2019
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Current state operating permit shall be displayed.