Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency alarm shall be made operational. Re-inspection required 8/18/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 3.26.10 Yes No Emergency battery lowering shall be made operational. Re-inspection required 8/18/2026
A17.1-1996 : Elevators 1.17 - Standby power operation 1002.2g (Standby Power Operation) Yes No Failed Cat 1 standby power test, battery lowering device failed to operate. Re-inspection required 9/9/2024
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No Car lighting is required to be protected against accidental contact and in a manner capable of containing broken glass 6/17/2026
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No OSV not sealed. Perform OSV test on or before next annual inspection. 3/10/2022
conversion conversion conversion - reinspect Yes No Reprogram cab hands free phone 4/26/2019