MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Emergency alarm shall be made operational. Re-inspection required
|
8/18/2026
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
3.26.10
|
Yes
|
No
|
Emergency battery lowering shall be made operational. Re-inspection required
|
8/18/2026
|
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7
|
No
|
No
|
Car lighting is required to be protected against accidental contact and in a manner capable of containing broken glass
|
6/17/2026
|
|
A17.1-1996 : Elevators
|
1.17 - Standby power operation
|
1002.2g (Standby Power Operation)
|
Yes
|
No
|
Failed Cat 1 standby power test, battery lowering device failed to operate. Re-inspection required
|
9/9/2024
|
|
A17.1-1996 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.5 Over Speed Valve Testing
|
No
|
No
|
OSV not sealed. Perform OSV test on or before next annual inspection.
|
3/10/2022
|
|
conversion
|
conversion
|
conversion - reinspect
|
Yes
|
No
|
Reprogram cab hands free phone
|
4/26/2019
|