conversion
|
conversion
|
n/a
|
|
|
Elevator machine room needs to be cleaned.
|
8/5/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
2/28/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.7 Cleaning of Hoistway and Pit
|
|
|
Clean the hoistway. There is excessive fuzz and lint throughout the hoistway.
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
The leveling at various floors needs to be adjusted.
|
8/1/2022
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Some electrical junction boxes in the hoistway are missing their covers.
|
8/1/2022
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Some electrical junction boxes on the car top are missing covers.
|
8/1/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)7
|
|
|
Verify the machine and generator are properly bonded and grounded.
|
8/1/2022
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
The pit lighting shall be a minimum of 5 foot-candles.
|
8/1/2022
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)12
|
|
|
All penetrations in the hoistway shall be patched.
|
8/1/2022
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
A few acrylic panels are missing from the car enclosure.
|
8/1/2022
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)3
|
|
|
The top emergency exit needs to be secured and able to open from the car top.
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
|
8/1/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)6
|
|
|
Label the disconnects with the source panel, name, location, and breaker numbers.
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
|
|
The hoistway door closer on the basement floor does not function properly.
|
8/1/2022
|
A17.1-2016 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
|