Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods the foam isolation pad on the tank lid is starting to decompose and fall into the hydraulic oil, the oil needs to be at least filtered and possibly replaced
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Repair light fixture in the machine room that is not working 8/13/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x the emergency light battery is dead, replace the battery 6/30/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate on display in the machine room expired in 2018, post the new copy when received from the state annually 8/1/2022