Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Handrail drive chain dragging on metal framework 8/28/2018
conversion conversion n/a No No Unit needs to be cleaned down 8/28/2018
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2 No No Unit needs clean down 3/2/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) No No Gear case seals leaking, evidence of oil on steps, correct problem 3/2/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(E) No Yes Ride side failed step skirt indexin 11/5/2020
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current state certificate in machine room 3/2/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No Provide maintenance control program on site posted on controller 3/2/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(B) No No Replace bottom level operating key switch 11/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(B) No No Replace lwer unit key operating Swithc does not self center 11/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Clean down truss 11/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5 Escalator or Moving Walk Startup No No Replace lower key operating switch. Does not self center 11/3/2025
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No POST CURRENT STATE CERTIFICATE 4/10/2026
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Top flat of left handrail starting to crack,has to be monitored biweekly until condition requires replacement.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5 Escalator or Moving Walk Startup No No Key switch to operate escalator needs to be replaced,not operating correctly.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index Yes No Step indexing failed. Reinspection required 30 days max 11/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.7 Rollers, Tracks, and Chains Yes No REPLACE WORN HANDRAILDRIVE CHAIN 4/10/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current MO State operating certificate in machine space.