machine room shall be kept clean and dry
|
|
conversion
|
conversion
|
n/a
|
|
|
No current state operation certificate in elevator machine room.
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
Car Door Restrictor does not work. Repair and Reinspect. 1.18
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Relocate tape selector mounting bracket on car top. Hits selector tape mounting bracket when doing stop ring pressure test
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces
|
|
|
Standing water on machine room floor and in front of controller creating electrical hazard
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Car shall have functioning Normal Terminal Limits actuating before Final Terminal Limit.
|
8/1/2022
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current Operating Certificate in machine room
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Selector Reader head hits selector tape mounting bracket during stop ring pressure test
|
8/1/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.4 Plunger Gripper Testing
|
|
|
Plunger Gripper due to be tested with rated load recurring every 5 years.
|
8/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Replace knocked out Down Hall Call Button at the second landing
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency Phone in car fails to establish two-way communication
|
|