MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)7
|
x
|
|
The car door closing force is greater than 30#.
|
9/21/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Alarm bell shall work properly. The alarm is working intermittently.
|
9/21/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
The emergency lighting shall work. 1 of the 2 bulbs are not working.
|
9/21/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
x
|
|
Detector edge shall not be powered by lighting circuit.
|
9/21/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
8/5/2021
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)4
|
x
|
x
|
Safety rope pullout greater than code allowance of 42". Currently at 45.5". Safety show clearances shall be adjusted to conform such that the pullout rope allowance is in compliance. Elevator Red Tagged.
|
9/21/2023
|