Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Yes No Detector edge shall not be powered by lighting circuit. 9/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/5/2021
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)4 Yes Yes Safety rope pullout greater than code allowance of 42". Currently at 45.5". Safety show clearances shall be adjusted to conform such that the pullout rope allowance is in compliance. Elevator Red Tagged. 9/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The emergency lighting shall work. 1 of the 2 bulbs are not working. 9/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Alarm bell shall work properly. The alarm is working intermittently. 9/21/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)7 Yes No The car door closing force is greater than 30#. 9/21/2023