MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
7/27/2021
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Car will not stop at floor 2 and 3 on phase 2 fire service and returns to floor 1.
|
8/2/2018
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Display current state operating certificate.
|
9/23/2019
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
|
Door re-opening device (eye ray), sensitive to smoke, shall be overridden during Phase 1 and Phase 2 fire service operation.
|
10/3/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
In cab emergency alarm bell shall work.
|
10/3/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)6
|
|
|
In cab emergency lights shall work.
|
9/23/2019
|
conversion
|
conversion
|
n/a
|
|
|
Oil Recovery Bucket Full, check seal.
|
9/23/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace expired battery in door restrictor control box.
|
9/23/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
The in car emergency light shall be operational.
|
11/28/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
There were no fire service keys to test fire service. Keys shall be kept on-site and fire service shall be tested.
|
11/28/2022
|