A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
the monthly fire service test log is not being filled out in the machine room
|
12/17/2020
|
|
A17.1-1996 : Elevators
|
5.11 Plunger and Cylinder
|
1206.5b(5) Oil Leakage Collection
|
|
|
Replace leaking jack gland seals, pit collection bucket overfills between maintenance visits
|
|
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
1206.2a
|
x
|
|
Pit bucket was overflowing, clean up oil on pit floor
|
|
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.5.7 Record of Oil Usage
|
|
|
Oil record log is not being filled out during maintenance visits, oil record log last filled out during 2024 annual inspection.
|
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters’ Emergency Operation Documentation
|
|
|
monthly fire service test log is not being filled out monthly
|
12/1/2021
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove oil absorbent pads from the pit floor
|
2/27/2026
|