Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Ceiling panels in car are open egg crate type and provide no protection in event of breakage. Replace with plastic tubes over bulbs.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Ceiling panels in car are open egg crate type and provide no protection in the event of breakage. Replace panels with plastic tubes over bulbs.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 12/28/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x x Fireman's recall stop switch did not stop work on recall while descending. 14 days to repair. Did not Red Tag. 8/19/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x Need to perform OSV testing. Re-inspection required 12/29/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Unit has oil recovery pump in pit, which is for temporary use only. Measurement of oil cannot be obtained.