Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x There were no keys on site to test fire service. Keys shall be kept on site and fire service shall be tested. 10/20/2020
MO Minimum : Elevators (A) - Hoistways (A)9 Unable to check in car stop switch upon Phase I recall,no key.
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) The machine room shall not be used for the storage of non-elevator related items. 10/26/2020
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) The machine room shall not be used for the storage of non-elevator related items. 10/26/2020
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Remove all non-elevator related items from the elevator machine room.
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Machine room shall not be used to store non-elevator related materials. 10/26/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)(12) x x Car call cancel does not function on Phase 2 fire service. 7/31/2019
A17.1-1996 : Elevators 1.17 - Standby power operation 1002.2g (Standby Power Operation) x Emergency battery lowering shall be operational. 1/30/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit sump shall have a cover in place.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The elevator pit shall be kept clean and dry. 10/26/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Emergency lighting is not operational. 10/26/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO state operating certificate shall be displayed in the elevator machine room.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve and is due for a category 5 test. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test.
conversion conversion conversion - reinspect x Phase 2 Firemans return call cancel does not operate. 7/18/2018