Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 2.37 - Pressure Switch 306.14 x There is no pressure switch. When cylinders are installed with the top of the cylinder above the top of the storage tank, a pressure switch shall be provided in the line between the cylinder and the valve, which shall be activated by the loss of positive pressure at the top of the cylinder.
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 102 x 102.2(c)(1) - Sprinklers pipes shall not run the entire hoistway. Customer may apply for a variance.
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The emergency phone shall work. There is no phone line.
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 102 x 102.2(c)(2) - Sprinkler branch lines in the hoistway shall supply sprinklers at not more than 1 floor level. Customer may apply for a variance.
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 5/12/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up-to-date operating certificate is required in the machine room. 5/12/2023