Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current copy of the state operating certificate in the machine room
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Post monthly fire service test log in the machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide access to the complete MCP in the machine room according to 8.6
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy annually. the certificate on display in the machine room is from 2019
A17.1-1996 : Elevators 4.2 - Hoistway doors 110 replace first floor hoistway door astragal, it is no longer glued to the bottom half of the door
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) clean up the oil on the pit floor
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b repair machine room air conditioner so it works
A17.1-2016 : Elevators 1.8 - Door closing force 8.11.3.1.1(h) x adjust the door close force to below 30 lbs, the doors maxed out my gauge (2.13.4.2.3) 6/16/2023
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x repair and adjusted door restrictor, it is not working 6/3/2024
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x Repair and adjust door restrictor, it is not working 8/30/2024