Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher is out of date. A current tested, ABC type fire extinguisher shall be provided in the machine room. 10/28/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.2 - Stop switches 2.26.2.5 x Stop switch shall be wired to alarm for audible notification.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room door shall be self-closing and self-locking.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.3 - Lighting and receptacles 8.11.2.1.2(c) Machine room lighting shall be 10 ftc at the floor. 12/6/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 12/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 8.11.2.1.2(h) Gutter and/or guard overhead pipes. 12/6/2018
conversion conversion n/a Fire extinguisher is out of date. 12/6/2018
conversion conversion n/a Machine room door shall be self-locking and self-closing. 12/6/2018
conversion conversion n/a All pipes above or in close proximity of the elevator equipment shall be guarded or guttered. 12/6/2018
conversion conversion n/a Lighting in the machine room shall be 10 foot candles at the floor. 12/6/2018
conversion conversion n/a Machine room shall be cleaned of all materials and equipment not necessary for the maintenance and operation of the elevator. 12/6/2018