Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)3 Replace missing door closer spring on Second Landing hall door 8/16/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. Re-inspection required
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Bulbs and tubes shall be guarded to prevent breakage 8/16/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Provide Phase II Fire Service Instructions on Car Operating Panel 8/16/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher is expired, needs to be serviced or replaced.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Car door restrictor is inoperable. When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening 1/5/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency Phone in car fails to establish two-way communication 1/5/2024
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) Need Phase II fire service instructions in car 5/29/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Alarm bell and emergency light don't work in car. 4/30/2020
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) Replace hoistway door rollers on floors 3,4 and 6. (Worn) 5/29/2020