MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
Two-way communication device shall work with and without main power.
|
8/3/2023
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)10 Car Floors
|
|
|
Cab floor to sill to hall floor shall be level and even. Currently, the cab and hall flooring are +1/2" above sill heights creating a tripping hazard. Repair/replace as needed.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
The correct elevator number shall be displayed on the crosshead.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
Adjust upthrust roller bearings for proper clearance to door hanger track.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Suspension means shall have proper data tag.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
The hoist motor and motor generator sets shall have junction box covers in place.
|
2/1/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room windows are broken and missing panes.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
4 x 4 electrical box in machine room needs to have wiring inside box and cover installed.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing, self-locking, and operable from the interior space without the use of a key.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Roof to machine room stairs are deteriorated, handrail has broken loose from concrete creating an unsafe condition. Repair/replace as needed to provide safe access.
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
The pit needs to be cleaned.
|
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)4
|
x
|
x
|
The safety drum rope shall not pullout more than 36". Currently pulls out 55".
|
9/8/2023
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)5
|
x
|
x
|
SOS switch will not reset. Take corrective action as needed.
|
9/8/2023
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)5
|
x
|
x
|
SOS switch will not reset. Take corrective action as needed.
|
8/3/2023
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)4
|
x
|
x
|
The safety drum rope shall not pullout more than 36". Currently pulls out 55". Red Tag Issued
|
8/3/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Ran into issues during testing. The following items shall be tested to complete the annual inspection and category 5 test: Testing of lights, alarm, and phone with 110v removed, Governor pull out/pull thru, governor electrical switch and jaw, slide, oil buffer test, 125 % weight test.
|
1/18/2022
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Wind up car safety rope shall be made of a non-corrosive material.
|
12/4/2018
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
There is no state operating certificate in the machine room.
|
|