MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
The hoist motor and motor generator sets shall have junction box covers in place.
|
2/1/2021
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Hoistway junction box at 6th floor shall have a cover.
|
2/1/2021
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current operating certificate shall be posted in the machine room in a non-combustible frame with a clear protective plate over it.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
Hoist motors and generators shall have junction box covers in place.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
A current ABC fire extinguisher shall be provided in the machine room
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Broken windows in machine room shall be repaired.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing & self-locking and open from the interior without the use of a key.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
x
|
|
Stairs to machine room are deteriorated and handrail is loose and a section at the landing is completely missing, creating a fall hazard. Repair/replace as needed to create a safe condition.
|
7/18/2025
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Wind up car safety rope shall be made of a non-corrosive material.
|
12/4/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
In cab emergency telephone shall work.
|
1/24/2019
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Fire service and door pressure shall be tested after SOS switch repaired to finish inspection.
|
7/18/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Safety operator (SOS) broke during testing and needs to be repaired.
|
7/18/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
x
|
Fire service panel at first floor is showing "trouble" error but smoke detectors are powered. Fire panel is completely non-functioning at this time. Elevator Red Tagged
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
x
|
Safety operator (SOS) broke during testing and needs to be repaired. Elevator Red Tagged.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency alarm bell is not functional.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Auxiliary lighting is not functional.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
x
|
|
Stairs to machine room are deteriorated and handrail is loose and a section at the landing is completely missing, creating a fall hazard. Repair/replace as needed to create a safe condition.
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Fire service and door pressure shall be tested after SOS switch repaired to finish inspection.
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(2)(C) Re-Inspection Required to Enforce.
|
x
|
|
The safety rope shall be made of a non-corrosive material.
|
1/18/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Unable to complete the annual inspection and category 5 test. The following items shall be tested to complete the inspection: Testing of emergency light, alarm, and bell with 110v removed, door pressure, slide, and oil buffer testing.
|
1/18/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
x
|
Fire service not operating correctly. Elevator Red Tagged.
|
4/29/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
The 2024 annual inspection still needs to be completed. All testing items remain.
|
4/29/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Fire service has been tested and red tag removed. The 2024 annual still needs to be completed.
|
6/17/2025
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency alarm bell is not functional.
|
7/18/2025
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Auxiliary lighting is not functional.
|
7/18/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Fire service panel at first floor is showing "trouble" error but smoke detectors are powered. Panel shall be repaired within 14 days or both elevators may be removed from service.
|
7/18/2025
|