Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)13 Hoistway shall be of solid construction. Repair hole left rear center at bottom landing. 1/25/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Provide existing emergency lights and bell to work. 6/18/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Emergency light lens is broken, replace.
MO Minimum : Elevators (I) - Pits (I)1 Remove standing water in pit 1/2/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2.3 (Elevator Emergency Power Illuminated Signal) x Elevators that are equipped to operate on emergency power shall have jewel to illuminate when operating on emergency power. 6/21/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 x Elevators that are equipped to operate on emergency power shall be tested. 6/21/2024
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.7.9.1 x 2.7.5.1 - Replace machine room light switch with standard switch (no motion or timer systems). 6/21/2024
A17.1-2016 : Elevators 2.4 - Machine space 2.1.3 x Machine room floor has holes that need to be covered. 6/21/2024
A17.1-2016 : Elevators 4.2 - Hoistway doors 8.6.4.13 Door Systems x Hoistway door secondary safety retainers/fire tabs shall be installed at bottom of all hoistway doors. 6/21/2024