MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Unable to test the emergency lighting.
|
3/22/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Phase II halo worn and unreadable
|
11/1/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Sheave seal worn and leaking, repair as needled
|
11/1/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
Need to replace missing door gibbs on the 1st, 4th & 8th floors
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Provide adequate machine room lighting.
|
3/22/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean the pit. The pit shall be kept clean.
|
11/1/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Pit shall be kept clean.
|
9/15/2020
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Pit light shall work.
|
3/22/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean pit
|
11/1/2021
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Need to replace defective hoist cables due to excessive rouge & diameter reduction. Re-inspection required in 90 days
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
211.7 Firefighters Operations/Signage
|
|
|
Post Phase I instructions near f/f switch
|
11/1/2021
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
|
Phase 2 fire service shall work.
|
10/4/2018
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
|
Phase 2 fire service shall work.
|
11/13/2018
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
x
|
Phase 2 fire service shall be operational.
|
1/15/2020
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
Provide MCP
|
11/1/2021
|