MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Annunciator needs cover
|
12/29/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
Close lattice at top of cab with solid non combustible material
|
12/29/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
x
|
No emergency alarm bell. Red tag unit until all violations are repaired
|
11/5/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)3
|
|
|
Install escape hatch cover lid. To be bolted shut to open from cartop without special tools
|
12/29/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)4
|
|
|
Basement hoistway door is plexiglass and its broken, replace with laminate glass
|
12/29/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)2
|
|
|
Close lattice at top of cab with solid, non-combustible material
|
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
x
|
Final limit does not function, Red tagged, Re-inspection required
|
1/30/2023
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)6
|
x
|
x
|
Gate switch does not function. Red tagged, Re-inspection required
|
1/30/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Annunciator needs a cover
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean debris out of pit
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)5
|
|
|
Need to install pit ladder. Pit deeper than 4 ft, extend ladder 4 ft above basement landing
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean debris out of pit, pit shall remain clean & dry
|
12/29/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)5
|
|
|
Pit deeper than 4 ft, install pit ladder. Extend 4 ft above basement landing
|
12/29/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Pit light of at least 5 FC shall be installed in pit, with switch accessible from basement door
|
12/29/2021
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Testing incomplete, need to do a safety soft set. Re-inspection required
|
1/30/2023
|