Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire Extinguisher in Machine Room is due to be serviced or replaced. Provide Fire Extinguisher in auxiliary machine space.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x The Emergency Phone in the car fails to establish two-way communication.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x x 8.6.4.16 The elevator shall be maintained to provide a stopping accuracy at the landings. The car is stopping 2" above the floor at each landing.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts x x The selector position cable is frayed and coming apart resulting in inconsistent stopping accuracy. The selector cable needs to be replaced.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Fire extinguisher in lower machine room is from 2015. Needs to be serviced. 4/22/2020