MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Fire extinguisher in lower machine room is from 2015. Needs to be serviced.
|
4/22/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Fire Extinguisher in Machine Room is due to be serviced or replaced. Provide Fire Extinguisher in auxiliary machine space.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
The Emergency Phone in the car fails to establish two-way communication.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
x
|
x
|
8.6.4.16 The elevator shall be maintained to provide a stopping accuracy at the landings. The car is stopping 2" above the floor at each landing.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
x
|
x
|
The selector position cable is frayed and coming apart resulting in inconsistent stopping accuracy. The selector cable needs to be replaced.
|
|