Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)1 Each passenger elevator hoistway landing shall be protected with a door or gate. The door or gate shall be of solid construction and shall guard the entire entrance. The 3rd floor hoistway door sight guard is missing and shall be replaced. 1/25/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Each passenger car shall have lighting inside the enclose of no less then 5 foot-candles. Bulbs and tubes shall be guarded to prevent breakage. 1/25/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers A current ABC fire extinguisher shall be provided in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The lobby hoist door is missing up thrust rollers. 8/31/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/31/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. 8/31/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Provide code compliant machine room lighting.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. 8/31/2021
MO Minimum : Elevators (H) - Machine Rooms (H)4 Equipment in the machine roon not being used in conjunction with the fuction or use of the elevator shall be removed.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective plate over it.